BusBabel

schneider electric-symmetra-px

electric-symmetra-px

Importata da documento

Mappa registri Modbus

50 registri

LenScalaEndian
1
Alarm/Status-register
Alarm/Status-register
alarm_status_register3uint1611R
2
Alarm/Status-register
Alarm/Status-register
alarm_status_register_23uint1611R
3
Alarm/Status-register
Alarm/Status-register
alarm_status_register_33uint1611R
4
Alarm/Status-register
Alarm/Status-register
alarm_status_register_43uint1611R
5
Alarm/Status-register
Alarm/Status-register
alarm_status_register_53uint1611R
6
Line-quality-00FF=acceptable-utility-line-quality-0000=unacceptable-utility-line-quality
Line-quality-00FF=acceptable-utility-line-quality-0000=unacceptable-utility-line-quality
line_quality_00ff_acceptable_utility_line_quality_0000_unacceptable_utility_line_quality3uint1611R
7
%-battery-capacity-remaining-battery-capacity-as-a-percent-of-the-fully-charged-condition-(0-100)
%-battery-capacity-remaining-battery-capacity-as-a-percent-of-the-fully-charged-condition-(0-100)
battery_capacity_remaining_battery_capacity_as_a_percent_of_the_fully_charged_condition_0_1003uint1611%R
8
Runtime-remaining
Runtime-remaining
runtime_remaining3uint1611minutesR
9
Battery-voltage-present-UPS-battery-voltage
Battery-voltage-present-UPS-battery-voltage
battery_voltage_present_ups_battery_voltage3uint1611VR
10
UPS-internal-temperature-(0-209)-00XX=valid-reading-FFXX=invalid-reading-XX=sensor-reading
UPS-internal-temperature-(0-209)-00XX=valid-reading-FFXX=invalid-reading-XX=sensor-reading
ups_internal_temperature_0_209_00xx_valid_reading_ffxx_invalid_reading_xx_sensor_reading3uint1611DCR
11
Amps-drawn-by-load
Amps-drawn-by-load
amps_drawn_by_load3uint1611AR
12
Number-of-battery-packs-with-bad-batteries
Number-of-battery-packs-with-bad-batteries
number_of_battery_packs_with_bad_batteries3uint1611eachR
13
Number-of-battery-packs
Number-of-battery-packs
number_of_battery_packs3uint1611eachR
14
UPS-output-load-as-a-percentage-of-full-rated-load-in-watts
UPS-output-load-as-a-percentage-of-full-rated-load-in-watts
ups_output_load_as_a_percentage_of_full_rated_load_in_watts3uint1611%R
15
Maximum-input-voltage-since-last-reading
Maximum-input-voltage-since-last-reading
maximum_input_voltage_since_last_reading3uint1611VR
16
Minimum-input-voltage-since-last-reading
Minimum-input-voltage-since-last-reading
minimum_input_voltage_since_last_reading3uint1611VR
17
Nominal-battery-voltage
Nominal-battery-voltage
nominal_battery_voltage3uint1611VR
18
Actual-battery-voltage
Actual-battery-voltage
actual_battery_voltage3uint1611VR
19
Utility-input-frequency
Utility-input-frequency
utility_input_frequency3uint1611HzR
20
Phase-A-utility-input-voltage
Phase-A-utility-input-voltage
phase_a_utility_input_voltage3uint1611VR
21
Phase-A-utility-input-current
Phase-A-utility-input-current
phase_a_utility_input_current3uint1611AR
22
Phase-A-bypass-input-voltage
Phase-A-bypass-input-voltage
phase_a_bypass_input_voltage3uint1611VR
23
Phase-A-percent-of-maximum-output-VA-@-N-+-0
Phase-A-percent-of-maximum-output-VA-@-N-+-0
phase_a_percent_of_maximum_output_va_n_03uint1611%R
24
Phase-A-percent-of-maximum-output-VA-@-N-+-x
Phase-A-percent-of-maximum-output-VA-@-N-+-x
phase_a_percent_of_maximum_output_va_n_x3uint1611%R
25
Phase-A-output
Phase-A-output
phase_a_output3uint1611kVAR
26
Phase-A-output-voltage
Phase-A-output-voltage
phase_a_output_voltage3uint1611VR
27
Phase-A-output-current
Phase-A-output-current
phase_a_output_current3uint1611AR
28
Phase-A-peak-output-current
Phase-A-peak-output-current
phase_a_peak_output_current3uint1611AR
29
Phase-B-utility-input-voltage
Phase-B-utility-input-voltage
phase_b_utility_input_voltage3uint1611VR
30
Phase-B-utility-input-current
Phase-B-utility-input-current
phase_b_utility_input_current3uint1611AR
31
Phase-B-bypass-input-voltage
Phase-B-bypass-input-voltage
phase_b_bypass_input_voltage3uint1611VR
32
Phase-B-percent-of-maximum-output-VA-@-N-+-0
Phase-B-percent-of-maximum-output-VA-@-N-+-0
phase_b_percent_of_maximum_output_va_n_03uint1611%R
33
Phase-B-percent-of-maximum-output-VA-@-N-+-x
Phase-B-percent-of-maximum-output-VA-@-N-+-x
phase_b_percent_of_maximum_output_va_n_x3uint1611%R
34
Phase-B-output
Phase-B-output
phase_b_output3uint1611kVAR
35
Phase-B-output-voltage
Phase-B-output-voltage
phase_b_output_voltage3uint1611VR
36
Phase-B-output-current
Phase-B-output-current
phase_b_output_current3uint1611AR
37
Phase-B-peak-output-current
Phase-B-peak-output-current
phase_b_peak_output_current3uint1611AR
38
Phase-C-utility-input-voltage
Phase-C-utility-input-voltage
phase_c_utility_input_voltage3uint1611VR
39
Phase-C-utility-input-current
Phase-C-utility-input-current
phase_c_utility_input_current3uint1611AR
40
Phase-C-bypass-input-voltage
Phase-C-bypass-input-voltage
phase_c_bypass_input_voltage3uint1611VR
41
Phase-C-percent-of-maximum-output-VA-@-N-+-0
Phase-C-percent-of-maximum-output-VA-@-N-+-0
phase_c_percent_of_maximum_output_va_n_03uint1611%R
42
Phase-C-percent-of-maximum-output-VA-@-N-+-x
Phase-C-percent-of-maximum-output-VA-@-N-+-x
phase_c_percent_of_maximum_output_va_n_x3uint1611%R
43
Phase-C-output
Phase-C-output
phase_c_output3uint1611kVAR
44
Phase-C-output-voltage
Phase-C-output-voltage
phase_c_output_voltage3uint1611VR
45
Phase-C-output-current
Phase-C-output-current
phase_c_output_current3uint1611AR
46
Phase-C-peak-output-current
Phase-C-peak-output-current
phase_c_peak_output_current3uint1611AR
47
Environmental-monitoring-card-temperature-reading-(Sensor-1)
Environmental-monitoring-card-temperature-reading-(Sensor-1)
environmental_monitoring_card_temperature_reading_sensor_13uint1611DCR
48
Environmental-monitoring-card-humidity-reading-(Sensor-1)
Environmental-monitoring-card-humidity-reading-(Sensor-1)
environmental_monitoring_card_humidity_reading_sensor_13uint1611%RHR
49
Environmental-monitoring-card-temperature-reading-(Sensor-2)
Environmental-monitoring-card-temperature-reading-(Sensor-2)
environmental_monitoring_card_temperature_reading_sensor_23uint1611DCR
50
Environmental-monitoring-card-humidity-reading-(Sensor-2)
Environmental-monitoring-card-humidity-reading-(Sensor-2)
environmental_monitoring_card_humidity_reading_sensor_23uint1611%RHR

Leggi questi registri via API

curl https://busbabel.vercel.app/api/devices/schneider/electric-symmetra-px/registers?version=v1