kohler decision-maker-550
decision-maker-550
Importata da documento
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | L2-L3-voltage L2-L3-voltage | l2_l3_voltage | 3 | uint16 | 1 | 1 | Volts AC | R | — | |
| 2 | L3-L1-voltage L3-L1-voltage | l3_l1_voltage | 3 | uint16 | 1 | 1 | Volts AC | R | — | |
| 3 | L1-l0-voltage L1-l0-voltage | l1_l0_voltage | 3 | uint16 | 1 | 1 | Volts AC | R | — | |
| 4 | L2-l0-voltage L2-l0-voltage | l2_l0_voltage | 3 | uint16 | 1 | 1 | Volts AC | R | — | |
| 5 | L3-l0-voltage L3-l0-voltage | l3_l0_voltage | 3 | uint16 | 1 | 1 | Volts AC | R | — | |
| 6 | L1-current L1-current | l1_current | 3 | uint16 | 1 | 1 | Amps AC | R | — | |
| 7 | L2-current L2-current | l2_current | 3 | uint16 | 1 | 1 | Amps AC | R | — | |
| 8 | L3-current L3-current | l3_current | 3 | uint16 | 1 | 1 | Amps AC | R | — | |
| 9 | Frequency Frequency | frequency | 3 | uint16 | 1 | 1 | Hz X 100 | R | — | |
| 10 | Total-kw Total-kw | total_kw | 3 | uint16 | 1 | 1 | kW | R | — | |
| 11 | Percent-of-rated-kw Percent-of-rated-kw | percent_of_rated_kw | 3 | uint16 | 1 | 1 | % Rated kW | R | — | |
| 12 | Total-power-factor Total-power-factor | total_power_factor | 3 | int16 | 1 | 1 | PF X 100 | R | — | |
| 13 | L1-kw L1-kw | l1_kw | 3 | uint16 | 1 | 1 | kW | R | — | |
| 14 | L1-power-factor L1-power-factor | l1_power_factor | 3 | int16 | 1 | 1 | PF X 100 | R | — | |
| 15 | L2-kw L2-kw | l2_kw | 3 | uint16 | 1 | 1 | kW | R | — | |
| 16 | L2-power-factor L2-power-factor | l2_power_factor | 3 | int16 | 1 | 1 | PF X 100 | R | — | |
| 17 | L3-kw L3-kw | l3_kw | 3 | uint16 | 1 | 1 | kW | R | — | |
| 18 | L3-power-factor L3-power-factor | l3_power_factor | 3 | int16 | 1 | 1 | PF X 100 | R | — | |
| 19 | Total-kvar Total-kvar | total_kvar | 3 | int16 | 1 | 1 | kVAR | R | — | |
| 20 | L1-kvar L1-kvar | l1_kvar | 3 | int16 | 1 | 1 | kVAR | R | — | |
| 21 | L2-kvar L2-kvar | l2_kvar | 3 | int16 | 1 | 1 | kVAR | R | — | |
| 22 | L3-kvar L3-kvar | l3_kvar | 3 | int16 | 1 | 1 | kVAR | R | — | |
| 23 | Total-kva Total-kva | total_kva | 3 | uint16 | 1 | 1 | kVA | R | — | |
| 24 | L1-kva L1-kva | l1_kva | 3 | uint16 | 1 | 1 | kVA | R | — | |
| 25 | L2-kva L2-kva | l2_kva | 3 | uint16 | 1 | 1 | kVA | R | — | |
| 26 | L3-kva L3-kva | l3_kva | 3 | uint16 | 1 | 1 | kVA | R | — | |
| 27 | Current-lead/lag Current-lead/lag | current_lead_lag | 3 | uint16 | 1 | 1 | Bits 0-1 Total Current - Leading = 10 Lagging = 01 Bits 2-3 L1 Current Leading = 10 Lagging = 01 Bits 4-5 L2 Current - Leading = 10 Lagging = 01 Bits 6-7 L3 Current - Leading = 10 Lagging = 01 | R | — | |
| 32 | Oil-pressure Oil-pressure | oil_pressure | 3 | uint16 | 1 | 1 | kPa/psi | R | — | |
| 33 | Coolant-temperature Coolant-temperature | coolant_temperature | 3 | int16 | 1 | 1 | Degrees C/Degrees F | R | — | |
| 34 | Engine-speed Engine-speed | engine_speed | 3 | uint16 | 1 | 1 | RPM | R | — | |
| 35 | Local-battery-voltage Local-battery-voltage | local_battery_voltage | 3 | uint16 | 1 | 1 | Volts DC X 10 | R | — | |
| 36 | Fuel-pressure Fuel-pressure | fuel_pressure | 3 | uint16 | 1 | 1 | kPa/psi DDEC/MDEC/ADEC only | R | — | |
| 37 | Fuel-temperature Fuel-temperature | fuel_temperature | 3 | int16 | 1 | 1 | Degrees C/Degrees F DDEC/MDEC/ADEC only | R | — | |
| 38 | Fuel-rate Fuel-rate | fuel_rate | 3 | uint16 | 1 | 1 | Liters/Hour X 100 or Gallons/Hour X 100 DDEC only | R | — | |
| 39 | Used-last-run Used-last-run | used_last_run | 3 | uint16 | 1 | 1 | Liters/Gallons DDEC only | R | — | |
| 40 | Coolant-pressure Coolant-pressure | coolant_pressure | 3 | uint16 | 1 | 1 | kPa/psi DDEC only | R | — | |
| 41 | Coolant-level Coolant-level | coolant_level | 3 | uint16 | 1 | 1 | % X 10 DDEC only | R | — | |
| 42 | Lube-oil-temperature Lube-oil-temperature | lube_oil_temperature | 3 | int16 | 1 | 1 | Degrees C/Degrees F DDEC/MDEC/ADEC/Waukesha only | R | — | |
| 43 | Oil-level Oil-level | oil_level | 3 | uint16 | 1 | 1 | % X 10 DDEC only | R | — | |
| 44 | Crankcase-pressure Crankcase-pressure | crankcase_pressure | 3 | uint16 | 1 | 1 | kPa/psi DDEC only | R | — | |
| 45 | Ambient-temperature Ambient-temperature | ambient_temperature | 3 | int16 | 1 | 1 | Degrees C/Degrees F DDEC only | R | — | |
| 46 | Ecm-battery-voltage Ecm-battery-voltage | ecm_battery_voltage | 3 | uint16 | 1 | 1 | Volts DC X 10 DDEC/MDEC/ADEC only | R | — | |
| 47 | Ecm-status Ecm-status | ecm_status | 3 | uint16 | 1 | 1 | 0 = DDEC-Equipped, 1 = Non-ECM, 2 = MDEC/ADEC-Equipped | R | — | |
| 48 | Intake-air-temperature Intake-air-temperature | intake_air_temperature | 3 | int16 | 1 | 1 | Degrees C/Degrees F MDEC/ADEC/Waukesha only | R | — | |
| 49 | Intake-air-pressure Intake-air-pressure | intake_air_pressure | 3 | uint16 | 1 | 1 | Degrees C/Degrees F MDEC/ADEC only | R | — | |
| 50 | Mdec/adec-fault-codes Mdec/adec-fault-codes | mdec_adec_fault_codes | 3 | uint16 | 1 | 1 | Numeric Fault Code MDEC/ADEC only | R | — | |
| 60 | Analog-input-00-(battery-voltage) Analog-input-00-(battery-voltage) | analog_input_00_battery_voltage | 3 | uint16 | 1 | 1 | Volts DC | R | — | |
| 61 | Analog-input01 Analog-input01 | analog_input01 | 3 | uint16 | 1 | 1 | User-defined and calibrated through the 550 controller. See the controller operation manual. | R | — | |
| 62 | Analog-input02 Analog-input02 | analog_input02 | 3 | uint16 | 1 | 1 | — | R | — | |
| 63 | Analog-input03 Analog-input03 | analog_input03 | 3 | uint16 | 1 | 1 | — | R | — |
Leggi questi registri via API
curl https://busbabel.vercel.app/api/devices/kohler/decision-maker-550/registers?version=v1